Simple and Cost-Effective OPC to SAP Solutions
Simple and Cost-Effective OPC to SAP Solutions
 
 
 Company
 
 Solution
 
 Case Studies
 
 Partners
 
 Certifications
 
 Compatibility
 
 Support
 
 Contact





OPC Compliance Logo

 
 SAP Certification Logo
 
 OPC Foundation Logo
           

Easily Connect OPC Compliant Plant Floor Systems to SAP

NLINK OPC TO SAP SOLUTION COMPATIBILITY

The NLINK® OPC to SAP Solution has been extensively and rigorously tested with all major releases of SAP R/3 and SAP ECC, and with a host of commercially available OPC DA, HDA and A&E servers providing unparalleled assurance that the NLINK OPC to SAP Solution will work flawlessly in your enterprise environment.

TECHNICAL SPECIFICATIONS

SAP RELEASES
SAP R/3
The NLINK OPC to SAP Solution has been successfully tested and/or deployed with the following releases of SAP R/3:
  • SAP R/3 3.1H
  • SAP R/3 4.0B
  • SAP R/3 4.5B
  • SAP R/3 4.6C
  • SAP R/3 4.7x100
  • SAP R/3 4.7x200
SAP ECC
The NLINK OPC to SAP Solution has been successfully tested and/or deployed with the following releases of SAP ECC:
  • SAP ECC 5.0
  • SAP ECC 6.0
NetWeaver
The NLINK OPC to SAP Solution works with or without NetWeaver and requires no additional SAP components or modules to be purchased or installed.
SAP PI (XI)
The NLINK OPC to SAP Solution works perfectly well with or without SAP Process Integration (PI), formerly known as SAP Exchange Infrastructure (XI).
SAP Certifications
The NLINK product, which provides the underlying technology platform for the NLINK OPC to SAP Solution, has achieved six separate SAP Certifications, (some of them multiple times), including Powered by NetWeaver and CA-ALE, over the past 12 years.
OPC DA SERVERS
OPC DA Servers

Version 2.00
Version 2.05a
Version 3.00
The NLINK OPC to SAP Solution has been successfully tested against the following commercially available OPC DA servers:
  • ABB Inc.:
    • AC800M OPC Server 5.0.7.34
  • Advosol Inc.:
    • OPC-DA Gateway Server to XML DA 4.0
    • DANSrv OPC DA .NET Server Toolkit 4.2.1
  • Chemstations, Inc.:
    • CHEMCAD 5.6.4
  • Cogent Real-Time Systems Inc.:
    • OPC DataHub 6.4
    • OPC DataHub 6.3
    • OPC DataHub 6.0.2
  • Cyberlogic Technologies, Inc.:
    • DHX OPC Server Suite 7.00
    • MBX OPC Server Suite 7.00
    • Validator 7.00
    • Cyberlogic OPC Server 6.00
  • ExperTune, Inc.:
    • ExperTune PlantTriage 7.4.4
  • GE Fanuc Intelligent Platforms:
    • Proficy HMI/SCADA - iFIX 4.5
    • Proficy HMI/SCADA - CIMPLICITY 7.0 Build 9039
  • Honeywell Inc.:
    • Uniformance PHD OPC DA/HDA Server 210.1.1
  • ICONICS, Inc.:
    • DataWorX32 OPC DA Server 9.0.165.0
    • DataWorX32 OPC Tunneling 9.0
  • InduSoft LLC:
    • Fluke DA OPC Server 4.0
  • Kepware Technologies:
    • KEPServerEX OPC Server V4.270.416
    • KEPServerEX OPC Server V4.222.376
    • KEPServerEX OPC Server V4.200.353
  • MatrikonOPC:
    • MatrikonOPC Universal Server 2.0.1.0
    • MatrikonOPC Universal Server 1.0.0.0
    • MatrikonOPC Desktop Historian™ 3.0.2.0
    • MatrikonOPC (Triconex/Simulation) 4.1.1.0
  • MSIndustrie Software GmbH:
    • MSIOPCServerPMA 1.1.0.4
    • MSIOPCServerNICE 1.1.0.4
    • MSIOPCServerW 1.1.0.4
  • National Instruments:
    • LabVIEW 8.0
  • OSIsoft Inc.:
    • PI DA/HDA Server 1.2.4.0
    • PI DA Server (spec 1.0, 2.0) 1.2.0.11
    • PI DA Server (spec 1.0, 2.0) 1.1.0.25
  • Rockwell Software Inc:
    • FactoryTalk Gateway 3.5.2.1
    • FactoryTalk Gateway 3.42.00
    • FactoryTalk Gateway 3.01.50
  • SENSYS Inc.:
    • IntelliMax v3.0
    • IntelliMax v3.5
  • Siemens AG:
    • Simatic NET OPC Servers V7.0
    • Simatic WinCC WinCC V6.2
    • Simatic WinCC WinCC V6.0 SP4
    • Simatic WinCC Connectivity Station V 6.2
    • Simatic WinCC Flexible 2008
  • Software Toolbox, Inc:
    • SLIK-DA OPC DA Server ActiveX/.NET Control 4.0
    • OmniServer Universal Configurable OPC Server 2.5.003
    • TOP Server OPC Servers 4.270.416
    • TOP Server OPC Servers 4.222.376
  • Takebishi Corporation:
    • DeviceXPlorer OPC Server 0.3
    • DeviceXPlorer MELSEC OPC Server 3.12.3
    • DeviceXPlorer MODBUS OPC Server 3.1.1.5
    • DeviceXPlorer FA-M3 OPC Server 3.1.1.5
    • DeviceXPlorer MELSEC OPC Server 3.1.1.5
    • DeviceXPlorer SYSMAC OPC Server 3.1.1.5
    • DeviceXPlorer TOYOPUC OPC Server 3.1.1.5
  • Triangle MicroWorks, Inc:
    • SCADA Data Gateway - Client and Server 2.38
  • Wonderware:
    • ABTCP DAServer 1.5.100
    • GESRTP DAServer 1.5.100
    • MBSerial DAServer 2.5.200
    • MBTCP DAServer 1.5.100
    • OMFINSEthernet DAServer 1.5.000
    • MTEthernet DAServer 1.5.000
    • FSGateway 1.5
    • ABCIP DAServer 4.0
    • DASABCIP v3.0.001
    • SIDIRECT DAServer 1.5.100
    • DASSIDirect 1.5
    • DAS SI Direct 1.1
  • Yokogawa Electric Corporation:
    • Exaopc OPC Interface Package R3.21
    • STARDOM "FCN/FCJ OPC Server for Windows" R1.80.01
OPC HDA SERVERS
OPC HDA Servers

Version 1.00
Version 1.1.0
Version 1.20
The NLINK OPC to SAP Solution has been successfully tested against the following commercially available OPC HDA servers:
  • Advosol Inc.:
    • HDANSrv OPC HDA .NET Server Toolkit Standard Edition 2.0
  • Canary Labs, Inc.:
    • Trend Historian - HDA Server & DA Client 6.1
  • Honeywell Inc.:
    • Uniformance PHD OPC DA/HDA Server 210.1.1
  • InduSoft LLC:
    • Fluke HDA OPC Server 4.0
  • MatrikonOPC:
    • MatrikonOPC Universal Server 2.0.1.0
    • MatrikonOPC Universal Server 1.0.0.0
    • Matrikon OPC Desktop Historian™ 3.3.0.0
    • Matrikon OPC Desktop Historian™ 3.0.2.0
  • OSIsoft Inc.:
    • PI HDA Server (spec 1.2) 1.2.4.0
    • PI HDA Server (spec 1.2) 1.2.0.11
    • PI HDA Server (spec 1.2) 1.1.0.25
    • ECHO HDA Server (spec 1.2) 1.0.0.31
  • SENSYS Inc.:
    • IntelliMax v3.0
  • Siemens AG:
    • Simatic WinCC WinCC V6.0 SP4
  • Yokogawa Electric Corporation:
    • Exaopc OPC Interface Package R3.21
OPC A&E SERVERS
OPC A&E Servers

Version 1.00
Version 1.02
Version 1.10
The NLINK OPC to SAP Solution has been successfully tested against the following commercially available OPC HDA servers:
  • ABB Inc.:
    • AC800M OPC Server 5.0.7.34
  • Cyberlogic Technologies, Inc.:
    • Cyberlogic OPC Server 6.00
    • DHX OPC Server Suite 7.00
    • MBX OPC Server Suite 7.00
    • Validator 7.00
  • GE Fanuc Intelligent Platforms:
    • Proficy HMI/SCADA CIMPLICITY 7.0.7.5
  • ICONICS, Inc.:
    • AlarmWorX32 OPC Alarm and Events Server 9.0.166.0
    • DataWorX32 OPC Tunneling 9.0
  • MatrikonOPC:
    • MatrikonOPC Universal Server 2.0.1.0
    • MatrikonOPC Universal Server 1.0.0.0
  • Mitsubishi Electric Corporation:
    • MX OPC Server 6.00
  • SENSYS Inc.:
    • IntelliMax v3.0
  • Siemens AG:
    • Simatic Net OPC Servers V7.0.0.0
    • Simatic WinCC V7.0
    • Simatic WinCC V6.0 SP4
    • Simatic WinCC Connectivity Station V7.0
    • Simatic Net OPC Servers V6.4.0.1
  • Yokogawa Electric Corporation:
    • Exaopc OPC Interface Package R3.21
  • Triangle MicroWorks, Inc:
    • SCADA Data Gateway - Client and Server 2.38
OPERATING SYSTEMS
Microsoft
The NLINK OPC to SAP Solution has been successfully tested and/or deployed in a production environment on the 32-bit and 64-bit versions of the following Microsoft Operating Systems:
  • Windows Server 2008
  • Windows Server 2003
Virtualization
The NLINK ADC to SAP Solution has been successfully tested and/or deployed in a production environment on the following commercial Virtualization Systems:
  • VMware
  • Microsoft Hyper-V



VIDEO PRESENTATIONS

There`s really only so much information you can absorb by reading about an enterprise software product like the NLINK OPC to SAP Solution. At some point you need to see the software in action and that`s what the NLINK OPC to SAP Solution Video Presentations are all about.

REQUEST AN NLINK OPC TO SAP DEMO

If you have already seen the Video Presentations and would like to learn more by scheduling a WebEx demonstration of the NLINK OPC to SAP Solution, please click here.


TECHNICAL INFORMATION
For more technical and product information regarding the NLINK OPC to SAP Solution please contact .

SALES AND PRICING INFORMATION
For sales and pricing information regarding the NLINK OPC to SAP Solution please contact .





Copyright © 1997 - 2012, Junot Systems, Inc. | Privacy Policy | Terms of Usage
sales@opc-to-sap.com | 713.479.7300 | Contact | Search